Earthquake provisions - Do these apply to houses and low rise structures?

November 19, 2019

A number of builders and designers have recently called asking whether Class 1 buildings are required to be designed to comply with AS 1170.4 – 2007 Earthquake Actions. The below information provides an overview of the compliance requirements in NCC 2019 Volume Two for earthquake design and detailing for Class 1 buildings.

NCC requirements

The NCC requires that earthquake actions be considered under Performance Requirement P2.1.1 Structural stability and resistance to actions. Part 3.0.1 outlines that the design of a building in accordance with AS 1170.4 will meet the Performance Requirements.

AS 1170.4 provides for simplified design for domestic structures (Class 1a and 1b) such that most houses are excluded from requiring specific detailing. However apartments, taller or larger homes, or those in high seismic activity areas will require detailed earthquake design and construction to suit.

So what are the NCC and Australian Standards requirements for earthquakes?

Earthquakes and AS1170.4

Earthquakes are high risk, low return events and it is therefore unreasonable to design every building to withstand all potential earthquakes. AS 1170.4 works to ensure the protection of people during an earthquake event, by allowing the building to withstand the quake long enough for people to exit the building.

AS 1170.4 maps out the seismic areas in Australia of greatest earthquake hazard. The hazard factor associated with the location of a structure is one of the key considerations in the overall design requirements for a building.

What does that all means for Class 1 buildings?

How does this affect houses and domestic buildings?

Appendix A of AS 1170.4 allows for simplified assessment of domestic structures (Class 1a and 1b buildings) less than 8.5 metres high and with a least plan-dimension of 16 metres, where traditional construction techniques are employed.

Importantly, houses within these criteria and located in areas where the hazard factor is 0.11 or less, do not require any additional earthquake detailing, as domestic structures are considered to perform sufficiently in an earthquake if they are designed for the local wind conditions.

Those houses with a third level, highly irregular plan or alternative construction methods are required to undergo a full assessment and include earthquake construction details to suit.

Houses proposed in locations where the hazard factor is 0.12 or greater that use traditional construction methods can have a simplified assessment completed, where it is likely that some construction detailing will still be required.

A quick guide to when a building needs seismic design

A building may require seismic design if:

  1. It is not Class 1 or 10 in accordance with the NCC; or
  2. If the site is located in an area where the hazard factor is greater than 0.11; or
  3. It has more than 2 levels, unless:
    • One level is entirely underground (note: basement with a garage door does not classify as fully underground)
    • The top level is a light loft with all walls within the roof; or
  4. If the structure is highly irregular in shape; or
  5. Has a least-plan dimension of more than 16m; or
  6. If the building is to be constructed from non-standard materials (such as rammed earth, hay bale construction and so on).

If a building falls into any of these categories, speak with your engineer and building approval body about the potential for earthquake design to be required. Even if a building does fall into these categories, it may not need any additional detailing.

For further information, please contact HIA Building Services on 1300 650 620